| Parameter | YFK-BZ3D | YFK-BZ5D | YFK-BZ5DII | YFK-BZ6D | YFK-BZ6SII | YFK-BZ8SII | YFK-BZ10SII | YFK-BZ15SII |
|---|---|---|---|---|---|---|---|---|
| Power supply | 220V | 220V | 380V | 220V | 380V | 380V | 380V | 380V |
| Heating capacity at 7℃ outside, kW | 9 | 14.6 | 14.6 | 16 | 16 | 22.3 | 32 | 40 |
| Heating capacity at −12℃ outside, kW | 6.4 | 10.5 | 10.5 | 11.8 | 11.8 | 15.5 | 20.6 | 25.5 |
| Heating capacity at −20℃ outside, kW | 5.4 | 9.5 | 9.5 | 10.5 | 10.5 | 13.5 | 16.6 | 21 |
| Cooling capacity at 35℃ outside, kW | 5.7 | 9 | 9 | 9.5 | 9.5 | 11.5 | 17 | 20 |
| Max. input power, kW | 3.4 | 6.4 | 6.4 | 6.6 | 6.6 | 8 | 12 | 13 |
| Noise, dB(A) | 60 | 60 | 60 | 62 | 62 | 62 | 62 | 62 |
| Max. water temperature | 55℃ | |||||||
| Refrigerant | R410A | |||||||
| Dimensions, mm | 770×353×910 | 938×392×1369 | 938×392×1369 | 938×392×1369 | 938×392×1369 | 938×392×1369 | 1118×425×1556 | 1118×425×1556 |
| Weight, kg | 57 | 90 | 90 | 98 | 95 | 122 | 170 | 185 |

| Parameter | YFKZ8D | YFKZ9D | YFKZ12D | YFKZ14D | YFKZ16D | YFKZ20D | YFKZ22D |
|---|---|---|---|---|---|---|---|
| Power supply | 220V (22D: 380V optional) | ||||||
| Heating capacity at 7℃ outside, kW | 8 | 9 | 12.8 | 14.6 | 16 | 20 | 23 |
| Heating capacity at −12℃ outside, kW | 5.2 | 6 | 8.7 | 10.5 | 11.6 | 13.5 | 15 |
| Heating capacity at −20℃ outside, kW | 4.55 | 4.86 | 7.13 | 9.6 | 9.8 | 11.6 | 12.5 |
| Cooling capacity at 35℃ outside, kW | 5.1 | 6 | 6.6 | 8.9 | 9.2 | 10 | 13 |
| Max. input power, kW | 3.08 | 3.4 | 5.2 | 6.4 | 6.6 | 7.05 | 8 |
| Noise, dB(A) | 58 | 58 | 58.5 | 59 | 59 | 59 | 59.5 |
| Max. water temperature | 55℃ | ||||||
| Refrigerant | R410A | ||||||
| Dimensions, mm | 845×320×695 | 910×353×770 | 938×392×1369 | 938×392×1369 | 938×392×1369 | 938×392×1369 | 938×392×1369 |
| Weight, kg | 50 | 76 | 115 | 130 | 130 | 130 | 145 |
Test conditions: heating at 7℃ outside with 45℃ water; at −12℃ and −20℃ outside with 41℃ water; cooling at 35℃ outside with 7℃ water. Specifications may change; the unit's nameplate prevails.

Commercial heat pumps (SHBR)
For schools, hotels, factories and office buildings. Runs at −30℃ to +43℃ outside. Modules combine and are controlled remotely.
| Parameter | SHBR-25IIA | SHBR-50IIA | SHBR-60IIA |
|---|---|---|---|
| Rated heating capacity (7℃ outside), kW | 69 | 155 | 168 |
| COP (heating) | 3.3 | 3.4 | 3.4 |
| Heating capacity at −12℃ outside, kW | 51 | 102 | 111 |
| Low-temperature heating capacity, kW | 43.44 | 86.88 | 94.55 |
| Cooling capacity at 35℃ outside, kW | 65 | 130 | 130 |
| Power supply | 380V / 3N / 50Hz | ||
| Max. current | 62 A | 125 A | 137 A |
| Protection rating | IPX4 | ||
| Refrigerant | R410A | ||
| Noise, dB(A) | ≤62 | ≤69 | ≤70 |
| Dimensions, mm | 2090×1100×2170 | 2270×1300×2250 | 2320×1200×2450 |
| Weight, kg | 700 | 1200 | 1300 |

Central hot water and heating for severe cold (KLR)
24-hour hot water for schools, hotels and factories. 3P to 60P, 8.3–171 kW. 380V power.
| Model | Size | Rated heating capacity (7℃ outside), kW | COP (heating) | Weight, kg |
|---|---|---|---|---|
| YFK-KLR030 | 3P | 8.3 | 3.46 | 105 |
| YFK-KLR050 | 5P | 15.8 | 3.76 | 145 |
| YFK-KLR060 | 6P | 18.4 | 3.54 | 162 |
| YFK-KLR070 | 7P | 22.1 | 3.74 | 182 |
| YFK-KLR080 | 8P | 23.8 | 3.6 | 188 |
| YFK-KLR100 | 10P | 33.12 | 3.6 | 312 |
| YFK-KLR120 | 12P | 36.8 | 3.49 | 350 |
| YFK-KLR150 | 15P | 42.6 | 3.49 | 420 |
| YFK-KLR200 | 20P | 62.4 | 3.51 | 582 |
| YFK-KLR250 | 25P | 73.6 | 3.5 | 650 |
| YFK-KLR300 | 30P | 88.2 | 3.5 | 825 |
| YFK-KLR400 | 40P | 114 | 3.5 | 1155 |
| YFK-KLR500 | 50P | 154.8 | 3.6 | 1385 |
| YFK-KLR600 | 60P | 171.2 | 3.42 | 1472 |
Heating capacity at 7℃ outside, water 40/45℃.
- Floor radiant cooling: chilled water runs through the underfloor heating pipes. 28–40% more efficient than ordinary air conditioning, with no cold draughts.
- Container-type prefabricated energy station (factory-built from a BIM model).
- Balancing valves, room temperature and humidity sensors.